<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>17744</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: unable to learn focus, change focus mode or shift plot
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Thermal</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Some focus modes do not support plotting from the edge of a plate. If at a
customer site running with diffusely reflecting plates change the focus mode to
4. If media is specular (mirror like) change to focus mode 0. If using a focus
mode required for development or debugging, shift the plot away from the edge
of the plate.
</text></DescriptionText>
<DescriptionText><text>
This error code applies to Thermal Head firmware version 1.30 and above.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Call service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Attempting to plot at the edge of the plate in focus modes other than 0 or 4.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/hdm_cal_fmode.xml</LinkAddress><LinkTitle>NVS: hdm fmode</LinkTitle></Link>
<Link><LinkAddress>../nvs/gc_cal_sssa.xml</LinkAddress><LinkTitle>NVS: gc sssa</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:46 2008 PST
</Updated>
<Links>
</Links>
</Error>